Palm Beach atlantic Apotheke cialis generika Wie können man apps auf android-Tablet herunterladen

TOPAG Lasertechnik GmbH
Nieder-Ramstädter Str. 247
64285 Darmstadt
Telefon: +49 6151 4259 78
Telefax: +49 6151 4259 88 
E- mail: info [at] topag.de 

Q2-1064 Serie

5961
Q2-1064 - Serie, gütegeschalteter Nd:YAG Laser, Dioden-gepumpt

Q2   1064

Quantas Q2-1064 models set new standard in Q-switched laser market. Q2 series diode pumped, fully air‑cooled lasers are designed for applications that require high peak power. Robust, reliable design is what makes this series ideal tool for applications like Laser Induced Breakdown Spectroscopy (LIBS), LCD repair, laser ablation, remote sensing and more. Broad selection of models are available offering 70mJ@50Hz or 40mJ@100Hz pulse energies.

Status-mail-unread-icon

Bezeichnungen der Tabs

  • Beschreibung
  • Spezifikationen
  • Bilder
Tab 1

Features

  • Up to 70mJ pulse energy
  • Air cooled (no water)
  • 20, 50 and 100Hz repetition rate
  • Built-in sync pulse generator for triggering of user equipment
  • Remote control via built-in Ethernet or Wi-Fi interface
  • Optional 2nd, 3rd, 4th or 5th harmonic generators
  • Optional attenuator for fundamental wavelength.
  • Guaranteed > 1 Gshot lifetime

Applications

  • Laser Induced Breakdown Spectroscopy (LIBS)
  • OPO, dye laser, Ti:saphire pumping
  • Remote sensing
  • Laser ablation
  • Time-of-Flight Spectroscopy (TOFS)
  • Laser Induced Fluorescence (LIF) Spectroscopy
  • Flash photolysis
  • Matrix Assisted Laser Desorption/Ionization (MALDI)
  • Pulsed Light Deposition (PLD)

Quantas Q2 models set new standard in Q-switched laser market. Q2 series diode pumped, fully air‑cooled, Q-switched lasers are designed for wide range of applications that require high peak power pulses. Robust, reliable design is what makes this series ideal tool for applications like Light Induced Breakdown Spectroscopy (LIBS), LCD repair, laser ablation, remote sensing and many others. Broad selection of models are available offering 70 mJ @ 50 Hz or 40 mJ @ 100 Hz pulse energies. Less than 10 ns pulse duration allows efficient fundamental wavelength conversion to higher harmonics with shortest wavelength available of 213 nm. Wavelenght extensions into infrared range by use of OPO are available by request. TEC based cooling eliminate risks associated with water cooling (like leaks, circuit shortening etc.) as well as reduce running cost due to no maintenance required. Low jitter triggering pulses for user equipment are available with up to 300 μs lead in internal triggering mode. If required, laser pulsing can be externally triggered from delay generator. Laser controlled via built-in Ethernet port trough web‑server with option to add Wi-Fi adapter. It allows users to monitor and control laser remotely.

Tab 2
Specifications 1)

ModelQuantas Q2-20Quantas Q2-50Quantas Q2-50HEQuantas Q2-100
Wavelength 1064 nm
Pulse energy 50 mJ 40 mJ 70 mJ 40 mJ
Typical pulse duration < 10 ns2)
Pulse to pulse energy stability4) < 0.5 % RMS3)
Power drift ± 3.0 %4)
Maximum pulse repetition rate5)  20 Hz
50 Hz 50 Hz 100 Hz
Beam profile bell-shaped, > 75 % fit to Gaussian
Beam divergence6) < 2 mrad
Polarization linear, horizontal
Typical beam diameter7) 3.5 mm
Jitter < 1 ns RMS 8)
Optional Harmonics Generator Module9)
532 nm 25 mJ 20 mJ 35 mJ  20 mJ
355 nm 15 mJ 12 mJ 20 mJ  12 mJ
266 nm 7 mJ 5 mJ 10 mJ  5 mJ
213 nm 2.5 mJ 1.5 mJ 3 mJ  1.5 mJ
Optional Attenuator10)
Wavelength 1064 nm, 532 nm, 355 nm
Attenuation range 5-95 %
Dimensions
Laser head (WxLxH) 190 x 408 x 120 mm3
Harmonics generator module (WxLxH) 160 x 242 x 112 mm3
Controller unit (WxLxH) 160 x 104 x 55 mm3
Power adapter, typical (WxLxH) 100 x 200 x 50 mm3
Operating Requirements
Cooling requirements air cooled
Ambient temperature 15 - 30 °C
Relative humidity 10 - 80 % (non-condensing)
Mains voltage 90 - 230 V AC, single phase, 47 - 63 Hz11)
Power consumption 100 W 150 W

1)Due to continuous improvements all specifications are subject to change. Unless stated therwise all specifications are measured at 1064 nm and maximum pulse repetition rate.

2)FWHM level at 1064 nm. Shorter pulse duration is available by request. Please inquire for detailed specifications.

3)Averaged from 30 second time interval.

4)Over 8 hour period after 20 minutes of warm-up when ambient temperature variation is ess than ±2 °C.

5)Factory-set pulse repetition rate is fixed at max repetition rate shown in the table. Higher repetition rates are available, please inquire for details.

6)Full angle measured at the 1/e² level.

7)Beam diameter is measured 20 cm from laser output at the 1/e² level.

8)In respect to Q-switch triggering edge of pulse.

9)Harmonics generator module is stand-alone unit optimized for specified output wavelength. Inquire for details if multiple wavelength output is needed.

10)Attenuator is built-in into harmonics generator module.

11)Laser can be powered from appropriate 28 V DC power source. Please inquire for details.

Tab 3

Tab 3 Inhalt

Tab 4

Tab 4 Inhalt

Tab 5
Bild 1
 Q2   1064
Beschreibung 1
Q2-1064 diode pumped air-cooled Q-switched laser
Bild 2
 Q2 1064 dimensions
Beschreibung 2
Q2-1064 dimensions laser head
Bild 3
 
Beschreibung 3
 
Bild 4
 
Beschreibung 4
 
Bild 5
 
Beschreibung 5
 
Bild 6
 
Beschreibung 6
 
Bild 7
 
Beschreibung 7
 
Bild 8
 
Beschreibung 8
 
Bild 9
 
Beschreibung 9
 
Bild 10
 
Beschreibung 10