NT260 Series - Narrow Linewidth 10 kHz Tunable Lasers

Tunable nanosecond laser NT262 with tuning range from 210 to 2600 nm stands out by its high repetition rate of 10 kHz and small linewidth <3 cm-1. The intregrated system consists of pump laser and OPO in a compact single housing.

Description 

Features

  • Hands-free no gap wavelength tuning in 210 - 2600 nm range
  • High repetition rate 10 kHz
  • Narrow linewidth down to 1.5 cm-1
  • Up to 0.7 W output
  • Monolithic rugged frame
  • Motorized output shutters
  • Mixed Q-switched/mode-locked operation
  • Easy control via keypad or PC

Applications

  • Laser-induced fluorescence spectroscopy
  • Photoacoustic microscopy
  • Metrology & equipment calibration
  • Pump-probe spectroscopy, photolysis
  • Mass spectroscopy
  • Environment monitoring, LIDAR

NT262 is a unique narrow linewidth 10 kHz OPO. Pioneering patented technology enables powerful up to 0.7 W output in 210 – 2600 nm wavelengths range while maintaining < 3 cm -1 (typically < 2 cm -1 at most wavelengths) linewidth that is highly beneficial for traditional and specific applications requiring narrow linewidth and high spectral brightness pulses. Thus, besides the most of popular applications, like fluorescence and pump-probe, the system is also suitable for such demanding applications where high resolution and narrow linewidth are required, like the calibration of detectors and spectroradiometers, metrology or gas spectroscopy. High 10 kHz repetition rate and hands-free wavelength tuning makes easy and fast experiment data collection as never before. The system is highly stable, ensures excellent short and long-term energy and power stability, has smaller M 2 value if compared with traditional OPO systems. In addition to superior specifications, the laser is highly reliable due to low generation threshold and easy running regime. The system fits into monolithic, rugged housing that ensure high reliability and low costs of maintenance.

Specifications 
Model 1) NT262
Wavelength range 2)
    Signal 405 - 710 nm
    Idler 710 - 2600 nm
    SH/SF generator (optional) 210 - 405 nm
Output pulse energy/ average power
    OPO 3) 70 µJ / 700 mW
    SH/SF generator (optional) 4) 6 µJ / 60 mW
Pulse duration 5) 7 ns
Repetition rate 10 kHz
Linewidth < 3 cm-1
Tuning resolution 6)
    Signal (405 - 710 nm) 0.5 cm-1
    Idler (710 - 2600 nm) 1 cm-1
    SH/SF (210 - 405 nm) 1 cm-1

1) Due to continuous improvement, all specifications are subject to change without notice. Parameters marked ‘typical’ are indications of typical performance (not specifications) and will vary with each unit we manufacture. Unless stated otherwise, all specifications are measured at 1064 nm and for basic system without options.

2) Hands-free tuning range is from 210 nm to 2600 nm. Wavelengths values at margins are rounded.

3) Measured at 450 nm. See tuning curves for typcial outputs at other wavelengths.

4) Measured at 230 nm. See tuning curves for typical outputs at other wavelengths.

5) FWHM measured with photodiode featuring 1 ns rise time and 300 MHz bandwidth oscilloscope.

6) For manual input from PC.

Options 

Please contact us for more details.

Documents 
Inquiry 
Do you have questions about NT260?
Your details will be gathered and handled to respond to your request.
Detailed information on this topic can be retrieved from our privacy policy.
  • Description
  • Specifications
  • Options
  • Documents
  • Inquiry

Features

  • Hands-free no gap wavelength tuning in 210 - 2600 nm range
  • High repetition rate 10 kHz
  • Narrow linewidth down to 1.5 cm-1
  • Up to 0.7 W output
  • Monolithic rugged frame
  • Motorized output shutters
  • Mixed Q-switched/mode-locked operation
  • Easy control via keypad or PC

Applications

  • Laser-induced fluorescence spectroscopy
  • Photoacoustic microscopy
  • Metrology & equipment calibration
  • Pump-probe spectroscopy, photolysis
  • Mass spectroscopy
  • Environment monitoring, LIDAR

NT262 is a unique narrow linewidth 10 kHz OPO. Pioneering patented technology enables powerful up to 0.7 W output in 210 – 2600 nm wavelengths range while maintaining < 3 cm -1 (typically < 2 cm -1 at most wavelengths) linewidth that is highly beneficial for traditional and specific applications requiring narrow linewidth and high spectral brightness pulses. Thus, besides the most of popular applications, like fluorescence and pump-probe, the system is also suitable for such demanding applications where high resolution and narrow linewidth are required, like the calibration of detectors and spectroradiometers, metrology or gas spectroscopy. High 10 kHz repetition rate and hands-free wavelength tuning makes easy and fast experiment data collection as never before. The system is highly stable, ensures excellent short and long-term energy and power stability, has smaller M 2 value if compared with traditional OPO systems. In addition to superior specifications, the laser is highly reliable due to low generation threshold and easy running regime. The system fits into monolithic, rugged housing that ensure high reliability and low costs of maintenance.

Model 1) NT262
Wavelength range 2)
Signal 405 - 710 nm
Idler 710 - 2600 nm
SH/SF generator (optional) 210 - 405 nm
Output pulse energy/ average power
OPO 3) 70 µJ / 700 mW
SH/SF generator (optional) 4) 6 µJ / 60 mW
Pulse duration 5) 7 ns
Repetition rate 10 kHz
Linewidth < 3 cm-1
Tuning resolution 6)
Signal (405 - 710 nm) 0.5 cm-1
Idler (710 - 2600 nm) 1 cm-1
SH/SF (210 - 405 nm) 1 cm-1

1) Due to continuous improvement, all specifications are subject to change without notice. Parameters marked ‘typical’ are indications of typical performance (not specifications) and will vary with each unit we manufacture. Unless stated otherwise, all specifications are measured at 1064 nm and for basic system without options.

2) Hands-free tuning range is from 210 nm to 2600 nm. Wavelengths values at margins are rounded.

3) Measured at 450 nm. See tuning curves for typcial outputs at other wavelengths.

4) Measured at 230 nm. See tuning curves for typical outputs at other wavelengths.

5) FWHM measured with photodiode featuring 1 ns rise time and 300 MHz bandwidth oscilloscope.

6) For manual input from PC.

Please contact us for more details.

Do you have questions about NT260?
Your details will be gathered and handled to respond to your request.
Detailed information on this topic can be retrieved from our privacy policy.

Do you have questions about our products?

Write to us | info@topag.de

Give us a call | +49 6151 42944 0

TOPAG Lasertechnik GmbH
Nieder-Ramstädter Str. 247
64285 Darmstadt, Germany
Phone: +49 6151 42944 0
Fax: +49 6151 42944 11
E-mail: info@topag.de