M266 - Versatile Monochromator / Spectrometer

The M266 is a compact versatile instrument with high aperture and low stray light and can be used as monochromator as well as flat field spectrograph. A wide range of options for the input port and two output ports, fully automated control of filters and up to 4-grating turret as well as a wide range of available detectors together with the versatile software provide excellent features for processing and analysis.

Description 

Features

  • High aperture ratio
  • Two output ports
  • Completely automated

Applications

  • Emission, fluorescence and Raman spectroscopy
  • Multi-channel spectroscopy
  • Absorption, reflection and transmission
  • Measurements from UV to IR

The M266 is our general-purpose high-aperture instrument with high line quality and low stray light performance, featuring 284mm focus and 30x10mm flat field.

Instrument Configuration

The M266 comprises one input port and two output ports. The input port may hold either a standard entrance slit, or a crossed entrance slit (optionally). All the spectral slits are automated; their width is adjusted by the instrument software. The slit design also contains a microscrew, which provides the possibility to manually adjust the opening width of the knives.

Depending on modification, the M266 may contain either a turret with four diffraction gratings, or one grating in the holder.

Specifications 

For more details, please download our product datasheet (pdf).

Model M266
Optical bench optimized Czerny-Turner with one input and two outputs
Spectral range typical 180 – 3600nm (depending on chosen gratings); extended up to 40µm (upon request)
Focal length 266 mm
Imaging option: available for the both output ports simultaneously
Gratings 50x50x10mm, one grating or a turret with 4 gratings from below1)
    Lines/mm1) 2400 1800 1200 600 400 300
    Spectral range2) 190 - 450 nm 190 - 540 nm 265 - 800 nm 500 - 1500 nm 660 - 800 nm 530 - 1600 nm 1130 - 2600 nm 1000 - 3000 nm 1330 - 3600 nm
    Spectral resolution < 0.05 nm < 0.08 nm < 0.11 nm < 0.22 nm < 0.22 nm < 0.35 nm < 0.47 nm < 0.47 nm
Integrated shutter computer-controlled, serves for measuring dark signal
Computer interface USB

1) Upon your request, diffraction gratings with another lines quantity/blazing angle can be used.

2) Wavelength range for which diffraction efficiency exceeds 40%.

Options 

The M266 monochromator-spectrograph has a wide range of options and accessories ensuring efficient collection of light from the sample located at a finite distance and in infinity, delivering light to the monochromator with and without an optical fiber, performing effective aperture matching of the optical fiber and monochromator. All the exit slits are equipped with precision focusing devices; and detector adapters allow easy detector focusing. Cassegrain lenses allow collecting light from objects located at a distance of 3.5m to infinity. Adapters PS-2 and PS-3 provide for the collection of light from a closely located sample and its effective input into an optical fiber. PS-2 features high transmittance in the UV range, while PS-3 has the possibility of installing an edge filter.

  • Order Separating Filters Wheels
  • Aperture Matching Adapters
  • Condensers for collecting light into the fiber
  • Condensers for collecting light into the monochromator
  • Crossed Entrance Slit (optionally installed instead of the Standard Entrance Slit)
  • Optical Fibers
  • Adapters for attaching CCD detectors
  • CCD detectors
  • Cassegrain lenses

Consult us to select the complete set of your monochromator-spectrograph that best meets the requirements of your instrument complex.

Documents 
Inquiry 
Do you have questions about M266?
Your details will be gathered and handled to respond to your request.
Detailed information on this topic can be retrieved from our privacy policy.
  • Description
  • Specifications
  • Options
  • Documents
  • Inquiry

Features

  • High aperture ratio
  • Two output ports
  • Completely automated

Applications

  • Emission, fluorescence and Raman spectroscopy
  • Multi-channel spectroscopy
  • Absorption, reflection and transmission
  • Measurements from UV to IR

The M266 is our general-purpose high-aperture instrument with high line quality and low stray light performance, featuring 284mm focus and 30x10mm flat field.

Instrument Configuration

The M266 comprises one input port and two output ports. The input port may hold either a standard entrance slit, or a crossed entrance slit (optionally). All the spectral slits are automated; their width is adjusted by the instrument software. The slit design also contains a microscrew, which provides the possibility to manually adjust the opening width of the knives.

Depending on modification, the M266 may contain either a turret with four diffraction gratings, or one grating in the holder.

For more details, please download our product datasheet (pdf).

Model M266
Optical bench optimized Czerny-Turner with one input and two outputs
Spectral range typical 180 – 3600nm (depending on chosen gratings); extended up to 40µm (upon request)
Focal length 266 mm
Imaging option: available for the both output ports simultaneously
Gratings 50x50x10mm, one grating or a turret with 4 gratings from below1)
Lines/mm1) 2400 1800 1200 600 400 300
Spectral range2) 190 - 450 nm 190 - 540 nm 265 - 800 nm 500 - 1500 nm 660 - 800 nm 530 - 1600 nm 1130 - 2600 nm 1000 - 3000 nm 1330 - 3600 nm
Spectral resolution < 0.05 nm < 0.08 nm < 0.11 nm < 0.22 nm < 0.22 nm < 0.35 nm < 0.47 nm < 0.47 nm
Integrated shutter computer-controlled, serves for measuring dark signal
Computer interface USB

1) Upon your request, diffraction gratings with another lines quantity/blazing angle can be used.

2) Wavelength range for which diffraction efficiency exceeds 40%.

The M266 monochromator-spectrograph has a wide range of options and accessories ensuring efficient collection of light from the sample located at a finite distance and in infinity, delivering light to the monochromator with and without an optical fiber, performing effective aperture matching of the optical fiber and monochromator. All the exit slits are equipped with precision focusing devices; and detector adapters allow easy detector focusing. Cassegrain lenses allow collecting light from objects located at a distance of 3.5m to infinity. Adapters PS-2 and PS-3 provide for the collection of light from a closely located sample and its effective input into an optical fiber. PS-2 features high transmittance in the UV range, while PS-3 has the possibility of installing an edge filter.

  • Order Separating Filters Wheels
  • Aperture Matching Adapters
  • Condensers for collecting light into the fiber
  • Condensers for collecting light into the monochromator
  • Crossed Entrance Slit (optionally installed instead of the Standard Entrance Slit)
  • Optical Fibers
  • Adapters for attaching CCD detectors
  • CCD detectors
  • Cassegrain lenses

Consult us to select the complete set of your monochromator-spectrograph that best meets the requirements of your instrument complex.

Do you have questions about M266?
Your details will be gathered and handled to respond to your request.
Detailed information on this topic can be retrieved from our privacy policy.

Do you have questions about our products?

Write to us | info@topag.de

Give us a call | +49 6151 42944 0

TOPAG Lasertechnik GmbH
Nieder-Ramstädter Str. 247
64285 Darmstadt, Germany
Phone: +49 6151 42944 0
Fax: +49 6151 42944 11
E-mail: info@topag.de