The M266 is a compact versatile instrument with high aperture and low stray light and can be used as monochromator as well as flat field spectrograph. A wide range of options for the input port and two output ports, fully automated control of filters and up to 4-grating turret as well as a wide range of available detectors together with the versatile software provide excellent features for processing and analysis.

Features
- High aperture ratio
- Two output ports
- Completely automated
Applications
- Emission, fluorescence and Raman spectroscopy
- Multi-channel spectroscopy
- Absorption, reflection and transmission
- Measurements from UV to IR
The M266 is our general-purpose high-aperture instrument with high line quality and low stray light performance, featuring 284mm focus and 30x10mm flat field.
Instrument Configuration
The M266 comprises one input port and two output ports. The input port may hold either a standard entrance slit, or a crossed entrance slit (optionally). All the spectral slits are automated; their width is adjusted by the instrument software. The slit design also contains a microscrew, which provides the possibility to manually adjust the opening width of the knives.
Depending on modification, the M266 may contain either a turret with four diffraction gratings, or one grating in the holder.
For more details, please download our product datasheet (pdf).
Model | M266 | ||||||||
Optical bench | optimized Czerny-Turner with one input and two outputs | ||||||||
Spectral range | typical 180 – 3600nm (depending on chosen gratings); extended up to 40µm (upon request) | ||||||||
Focal length | 266 mm | ||||||||
Imaging | option: available for the both output ports simultaneously | ||||||||
Gratings | 50x50x10mm, one grating or a turret with 4 gratings from below1) | ||||||||
Lines/mm1) | 2400 | 1800 | 1200 | 600 | 400 | 300 | |||
Spectral range2) | 190 - 450 nm | 190 - 540 nm | 265 - 800 nm | 500 - 1500 nm | 660 - 800 nm | 530 - 1600 nm | 1130 - 2600 nm | 1000 - 3000 nm | 1330 - 3600 nm |
Spectral resolution | < 0.05 nm | < 0.08 nm | < 0.11 nm | < 0.22 nm | < 0.22 nm | < 0.35 nm | < 0.47 nm | < 0.47 nm | |
Integrated shutter | computer-controlled, serves for measuring dark signal | ||||||||
Computer interface | USB |
1) Upon your request, diffraction gratings with another lines quantity/blazing angle can be used.
2) Wavelength range for which diffraction efficiency exceeds 40%.
The M266 monochromator-spectrograph has a wide range of options and accessories ensuring efficient collection of light from the sample located at a finite distance and in infinity, delivering light to the monochromator with and without an optical fiber, performing effective aperture matching of the optical fiber and monochromator. All the exit slits are equipped with precision focusing devices; and detector adapters allow easy detector focusing. Cassegrain lenses allow collecting light from objects located at a distance of 3.5m to infinity. Adapters PS-2 and PS-3 provide for the collection of light from a closely located sample and its effective input into an optical fiber. PS-2 features high transmittance in the UV range, while PS-3 has the possibility of installing an edge filter.
- Order Separating Filters Wheels
- Aperture Matching Adapters
- Condensers for collecting light into the fiber
- Condensers for collecting light into the monochromator
- Crossed Entrance Slit (optionally installed instead of the Standard Entrance Slit)
- Optical Fibers
- Adapters for attaching CCD detectors
- CCD detectors
- Cassegrain lenses
Consult us to select the complete set of your monochromator-spectrograph that best meets the requirements of your instrument complex.
- Specifications
- Options
- Documents
- Inquiry
Features
- High aperture ratio
- Two output ports
- Completely automated
Applications
- Emission, fluorescence and Raman spectroscopy
- Multi-channel spectroscopy
- Absorption, reflection and transmission
- Measurements from UV to IR
The M266 is our general-purpose high-aperture instrument with high line quality and low stray light performance, featuring 284mm focus and 30x10mm flat field.
Instrument Configuration
The M266 comprises one input port and two output ports. The input port may hold either a standard entrance slit, or a crossed entrance slit (optionally). All the spectral slits are automated; their width is adjusted by the instrument software. The slit design also contains a microscrew, which provides the possibility to manually adjust the opening width of the knives.
Depending on modification, the M266 may contain either a turret with four diffraction gratings, or one grating in the holder.
For more details, please download our product datasheet (pdf).
Model | M266 | ||||||||
Optical bench | optimized Czerny-Turner with one input and two outputs | ||||||||
Spectral range | typical 180 – 3600nm (depending on chosen gratings); extended up to 40µm (upon request) | ||||||||
Focal length | 266 mm | ||||||||
Imaging | option: available for the both output ports simultaneously | ||||||||
Gratings | 50x50x10mm, one grating or a turret with 4 gratings from below1) | ||||||||
Lines/mm1) | 2400 | 1800 | 1200 | 600 | 400 | 300 | |||
Spectral range2) | 190 - 450 nm | 190 - 540 nm | 265 - 800 nm | 500 - 1500 nm | 660 - 800 nm | 530 - 1600 nm | 1130 - 2600 nm | 1000 - 3000 nm | 1330 - 3600 nm |
Spectral resolution | < 0.05 nm | < 0.08 nm | < 0.11 nm | < 0.22 nm | < 0.22 nm | < 0.35 nm | < 0.47 nm | < 0.47 nm | |
Integrated shutter | computer-controlled, serves for measuring dark signal | ||||||||
Computer interface | USB |
1) Upon your request, diffraction gratings with another lines quantity/blazing angle can be used.
2) Wavelength range for which diffraction efficiency exceeds 40%.
The M266 monochromator-spectrograph has a wide range of options and accessories ensuring efficient collection of light from the sample located at a finite distance and in infinity, delivering light to the monochromator with and without an optical fiber, performing effective aperture matching of the optical fiber and monochromator. All the exit slits are equipped with precision focusing devices; and detector adapters allow easy detector focusing. Cassegrain lenses allow collecting light from objects located at a distance of 3.5m to infinity. Adapters PS-2 and PS-3 provide for the collection of light from a closely located sample and its effective input into an optical fiber. PS-2 features high transmittance in the UV range, while PS-3 has the possibility of installing an edge filter.
- Order Separating Filters Wheels
- Aperture Matching Adapters
- Condensers for collecting light into the fiber
- Condensers for collecting light into the monochromator
- Crossed Entrance Slit (optionally installed instead of the Standard Entrance Slit)
- Optical Fibers
- Adapters for attaching CCD detectors
- CCD detectors
- Cassegrain lenses
Consult us to select the complete set of your monochromator-spectrograph that best meets the requirements of your instrument complex.
Do you have questions about our products?
Write to us | info@topag.de
Give us a call | +49 6151 42944 0
TOPAG Lasertechnik GmbH
Nieder-Ramstädter Str. 247
64285 Darmstadt, Germany
Phone: +49 6151 42944 0
Fax: +49 6151 42944 11
E-mail: info@topag.de